Mass balance
Write the balance before reaching for a process formula: accumulation = in − out + generation − consumption. At steady state with a conservative substance, two joining streams mix to the flow-weighted average concentration. For a reacting substance the same balance, applied to a completely mixed vessel, produces the reactor equations used across the treatment areas. Flow measurement — weirs, flumes and meters — supplies the Q that every balance needs; a sharp-crested weir turns a measured head into a flow.
Steady mixing: C = (Q1C1 + Q2C2)/(Q1 + Q2) · Load (lb/d) = Q (MGD) × C (mg/L) × 8.34
Worked example Mixing two waste streams
Given: A plant receives 2.0 MGD at 200 mg/L BOD and 0.5 MGD at 50 mg/L BOD. Find the blended BOD concentration.
Solution:
- Mass in, in flow × concentration units: 2.0 × 200 + 0.5 × 50 = 400 + 25 = 425.
- Total flow: 2.0 + 0.5 = 2.5 MGD.
- C = 425 / 2.5 = 170 mg/L.
Answer: Blended BOD = 170 mg/L.
Hydraulic loading
Hydraulic loading rates size surface-driven processes. The surface overflow rate of a clarifier is SOR = Q/A — the upward velocity the flow would have if it rose evenly through the tank — and a particle settles out only if its settling velocity exceeds it. Detention time, θ = V/Q, sizes volume-driven processes, and weir loading, Q per unit length of weir, checks that the exit flow does not drag solids over the launder.
SOR = Q/A · θ = V/Q · Weir loading = Q / weir length
Worked example Clarifier surface overflow rate
Given: A circular clarifier 80 ft in diameter receives 2.0 MGD. Find the surface overflow rate.
Solution:
- Area A = π × 40² = 5,027 ft².
- SOR = 2,000,000 gal/day / 5,027 ft² = 398 gal/day/ft².
Answer: SOR ≈ 398 gpd/ft².
Solids loading
A clarifier can pass its hydraulic check and still fail on solids: the solids loading rate applies the solids flux — flow times concentration — to the same surface area. In an activated-sludge secondary clarifier the flux uses the combined flow (plant flow plus return sludge) at the mixed-liquor concentration. The 8.34 factor converts MGD × mg/L into lb/day; forgetting the return flow in the numerator is the classic error.
Solids loading = (Q + Qr) × MLSS × 8.34 / A (lb/day/ft², flows in MGD)
Worked example Solids loading on a secondary clarifier
Given: A clarifier of area 2,000 ft² receives plant flow of 1.0 MGD (neglect return flow for this check) at MLSS 2,000 mg/L. Find the solids loading rate.
Solution:
- Solids applied: 1.0 × 2,000 × 8.34 = 16,680 lb/day.
- Divide by area: 16,680 / 2,000 = 8.34 lb/day/ft².
Answer: Solids loading = 8.34 lb/day/ft².